Metal Roof with Raked Ceiling RT 3.26
Outside air film, metal roof 1º to 5º pitch, 40mm nominal airspace, Polyair Multi, 100mm unventilated ceiling cavity airspace, raked ceiling, indoor air film.
Building System Certification Analysis
| Product: | Polyair Multi |
| Thickness = 9mm Thermal Break = 0.22 Fire Test AS1530.2 = 0 Refer to the Polyair product specification for further certification and performance testing results. |
|
| R-Value Calculation: | RT 3.26 (Heat Flow Down) RT 1.51 (Heat Flow Up) |
| Calculated by James Fricker, F.AIRAH, M.EngAust, CPEng |
|
| Calculation Endorsement: | RT 3.26 (Heat Flow Down) RT 1.51 (Heat Flow Up) |
| Endorsed by David W.Yarbrough, PhD, PE (R&D Services, Inc) |
BCA Section J
| Minimum Requirement: | RT 3.2 (Heat Flow Down) |
| R-Value requirement for conditioned floor space. Applicable to building class: 5, 6, 7, 8, 9a, 9b Applicable to climate zones: 1, 2, 3, 4, 5, 6 For full details refer to BCA 2009, Vol1, Section J Table J1.3 Roofs and Ceilings |
The contribution of this product to the Total R-Value depends on the installation and environmental conditions. The values shown are Total R-Values for the building system, calculated using Reflect 3 computer software validated by James M Fricker F.AIRAH, M.EngAust, CPEng and are based on installed product service in accordance with AS/NZS 4859.1:2002. Verified by R&D Services Inc. Refer to the Polyair technical manual or website for further details.