Framed Floor with Exposed Subfloor RT 2.21
Inside air film, 19mm plywood floor, 60mm nominal airspace, Polyair Super, exposed subfloor.
Building System Certification Analysis
| Product: | Polyair Super |
| Thickness = 4.5mm Fire Test AS1530.2 = 5 Refer to the Polyair product specification for further certification and performance testing results. |
|
| R-Value Calculation: | RT 2.21 (Heat Flow Down) RT 1.31 (Heat Flow Up) |
| Calculated by James Fricker, F.AIRAH, M.EngAust, CPEng |
|
| Calculation Endorsement: | RT 2.21 (Heat Flow Down) RT 1.31 (Heat Flow Up) |
| Endorsed by David W.Yarbrough, PhD, PE (R&D Services, Inc) |
BCA Section J
| Minimum Requirement: | RT 1.5 (Heat Flow Down) |
| R-Value requirement for conditioned floor space. Applicable to building class: 5, 6, 7, 8, 9a, 9b Applicable to climate zones: 4, 6, 7, 8 For full details refer to BCA 2009, Vol1, Section J Table J1.6 Floors |
The contribution of this product to the Total R-Value depends on the installation and environmental conditions. The values shown are Total R-Values for the building system, calculated using Reflect 3 computer software validated by James M Fricker F.AIRAH, M.EngAust, CPEng and are based on installed product service in accordance with AS/NZS 4859.1:2002. Verified by R&D Services Inc. Refer to the Polyair technical manual or website for further details.