Design Solutions
Concrete Tilt Slab Wall RT 1.90
Outside air film, 150mm concrete tilt slab wall, 20mm nominal airspace,
Polyair Super, 20mm nominal airspace, plasterboard lining, indoor air film.
Building System Certification Analysis
| Product: | Polyair Super |
| Thickness = 4.5mm Fire Test AS1530.2 = 5 Refer to the Polyair product specification for further certification and performance testing results. |
|
| R-Value Calculation: | RT 1.90 (Wall) |
| Calculated by James Fricker, F.AIRAH, M.EngAust, CPEng |
|
| Calculation Endorsement: | RT 1.90 (Wall) |
| Endorsed by David W.Yarbrough, PhD, PE (R&D Services, Inc) |
BCA Section J
| Minimum Requirement: | RT 1.8 (Wall) |
| R-Value requirement for conditioned floor space. Applicable to building class: 5, 6, 7, 8, 9a, 9b Applicable to climate zones: 1, 2, 3, 4, 5, 6 For full details refer to BCA 2009, Vol1, Section J Table J1.5b External Walls |
The contribution of this product to the Total R-Value depends on the installation and environmental conditions. The values shown are Total R-Values for the building system, calculated using Reflect 3 computer software validated by James M Fricker F.AIRAH, M.EngAust, CPEng and are based on installed product service in accordance with AS/NZS 4859.1:2002. Verified by R&D Services Inc. Refer to the Polyair technical manual or website for further details.